Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity

2018

Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …

1144ApertureZernike polynomialsmedicine.medical_treatmentintraocular lensIntraocular lensStandard deviationlaw.invention03 medical and health sciencessymbols.namesake0302 clinical medicineOpticslcsh:OphthalmologylawMedicinerepeatabilityoptical qualitybusiness.industryRepeatabilityOptical qualityToric lensLens (optics)Ophthalmologyin-vitro measurementslcsh:RE1-994030221 ophthalmology & optometrysymbolsbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes

2009

Purpose: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results: Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied …

Accuracy and precisionamplitude of accommodationgenetic structuresComputer scienceAcousticssubjective methods050105 experimental psychology03 medical and health sciencesimage quality metricsobjective methods0302 clinical medicinelcsh:Ophthalmologymedicineamplitud de acomodaciónlcsh:QC350-4670501 psychology and cognitive sciencesmétodos subjetivosSimulationWavefrontmétricas de calidad de imagenmétodos objetivos05 social sciencespresbiciaPresbyopiamedicine.diseaseOptical qualityAmplitude of accommodationlcsh:RE1-994030221 ophthalmology & optometrypresbyopiaOriginal Articlelcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool

2021

Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …

AdultMalediscomfortiris colormedicine.medical_specialtyBiometrygenetic structuresPhotophobiaPopulationVision DisordersBiomedical EngineeringFrequency of usepupilAudiologyArticleIris colorYoung AdultHumansMedicineeducationFatigueAgededucation.field_of_studyLight sensitivitysunglasses usebusiness.industryskin toneGlare (vision)ChronotypeglareMiddle AgedOptical qualityOphthalmologyEyeglasseschronotypeFemalehealthy populationmedicine.symptomlightbusinessTranslational Vision Science & Technology
researchProduct

Ophthalmic: Laboratorio virtual para el diseño de nuevas lentes oftálmicas

2013

This work presents a new virtual laboratory, OPHTALMIC, developed with MATLAB GUI for using in Optics and Optometry courses as a computer tool for studying the focusing properties of multifocal diffractive both on unconventional structures both periodic and aperiodic. This virtual laboratory enables students to quickly and easily analyze the influence of the different parameters of construction and find the best solution for a user.

Engineering drawingEngineeringComputer toolsbusiness.industryCantor setOptical qualitylcsh:Education (General)Multifocal intraocular lensAperiodic graphVirtual LaboratoryMATLABbusinesslcsh:L7-991computercomputer.programming_languageModelling in Science Education and Learning
researchProduct

Effect of Decentration on the Optical Quality of Two Intraocular Lenses

2016

To analyze the effect of decentration on the optical quality of two diffractive-refractive intraocular lenses, a bifocal and a trifocal, when displaced laterally (horizontal direction) from the center.The AT LISA 809M IOL (+3.75 D add) with two main foci and the AT LISA tri 839MP intraocular lens with three main foci (Carl Zeiss Meditec AG, Jena, Germany) were analyzed. The optical quality of the intraocular lenses was measured with the PMTF (power and modulation transfer function [MTF] measurement for refractive and diffractive intraocular lenses) optical bench (Lambda-X, Nivelles, Belgium). The optical quality of the lenses was evaluated by the MTF at different object vergences, the avera…

Lenses IntraocularOptics and Photonicsbusiness.industryVision TestsProsthesis DesignRefraction OcularRefractionOptical quality03 medical and health sciencesOphthalmologyOcular physiology0302 clinical medicineOpticsIntraocular lenses030221 ophthalmology & optometryHumansProsthesis designOptometryVision testbusinessVision Ocular030217 neurology & neurosurgeryGeologyOptometryOptometry and Vision Science
researchProduct

Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses

2014

Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…

Lenses IntraocularWavefrontPhysicsOptics and PhotonicsCorneal Wavefront Aberrationbusiness.industryZernike polynomialsAberrometryAstigmatismComa (optics)General MedicineModels TheoreticalOptical qualityOphthalmologyAlcon LaboratoriesSpherical aberrationsymbols.namesakeOpticsLens Implantation IntraocularIntraocular lensesAberrometrysymbolsHumansbusinessEuropean Journal of Ophthalmology
researchProduct

Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic.

2008

PURPOSE: To retrospectively report the trends of change in several parameters of the human visualsystem over a wide age range in patients attending an eye clinic. SETTING: University of Valencia, Valencia, Spain. METHODS: The clinical records of 2654 patients were retrospectively reviewed, and the age, sex, spherocylindrical refraction, visual acuity, keratometry, and intraocular pressure were obtained. Descriptive values for each parameter and the correlations with age and between different parameters were calculated. Vectorial components of refraction, including blur, were also derived from clinical refractive data and then analyzed. RESULTS: Several parameters changed significantly with …

MaleRefractive errorAgingVisual acuitygenetic structuresVisual Acuity0302 clinical medicineMyopiaPrevalence10. No inequalityChildAged 80 and overMiddle AgedRefractive ErrorsSensory SystemsOptical qualitymedicine.anatomical_structureChild PreschoolHuman visual system modelFemalemedicine.symptomAdultmedicine.medical_specialtyAdolescentVision DisordersAstigmatismRefraction Ocular03 medical and health sciencesAgeAge DistributionAge relatedOphthalmologymedicineHumansIn patientIntraocular PressureVision OcularAgedRetrospective StudiesScience & Technologybusiness.industryRefractive errorInfantmedicine.diseaseeye diseasesOphthalmologyCross-Sectional Studies030221 ophthalmology & optometryOptometrySurgeryHuman eyesense organsbusiness030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct

Optical quality after instillation of eyedrops in dry-eye syndrome

2010

Purpose To study the effect of eyedrop instillation on the optical quality of the air–tear film interface at the anterior cornea in cases of dry eye. Setting University of Valencia, Valencia, Spain. Methods Corneal aberrations (total, spherical-like, and coma-like) were determined from corneal elevation maps and purpose-designed software in cases of dry eye before, immediately after, and 10 minutes after lubricating eyedrop instillation (Blink Intensive Tears). All data were decomposed using Zernike polynomials to yield the root-mean-square wavefront deviations for pupil diameters of 3.0 mm and 5.5 mm. Outcome measures included comparison with clinical tear breakup time (TBUT). Results Wave…

Malemedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersDry Eye SyndromesPupilCorneaCorneaOphthalmologymedicineHumansmedicine.diagnostic_testbusiness.industryAirCorneal TopographyMiddle Agedmedicine.diseaseCorneal topographyeye diseasesSensory SystemsOptical qualityOphthalmologyArtificial tearsmedicine.anatomical_structureTearsTearsDry Eye SyndromesFemaleSurgerysense organsOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

High Optical Quality Films of Liquid Crystalline Cellulose Derivatives in Acrylates

2013

Materials sciencePolymers and PlasticsLiquid crystallineOrganic ChemistryCellulose derivativesCondensed Matter PhysicsOptical qualityChemical engineeringLiquid crystalPolymer chemistryMaterials ChemistryOrganic chemistryPhysical and Theoretical ChemistryPhotonic crystalMacromolecular Chemistry and Physics
researchProduct

Optical, thermal, electrical, damage, and phase-matching properties of lithium selenoindate

2011

LiInSe2, a biaxial nonlinear crystal transparent from 0.54 to 10 µm, is successfully grown in large sizes with good optical quality. We summarize all characteristics and physical properties of LiInSe2 essential for nonlinear frequency conversion.

Materials sciencebusiness.industrychemistry.chemical_elementOptical qualityCrystalNonlinear systemsymbols.namesakeOpticschemistryThermalsymbolsLithiumbusinessRaman spectroscopyRefractive indexPhase matching
researchProduct